          Coriolis Mass Flowmeter High Viscosity Mass Flow Meter Micro mass flow meter Heat Tracing Jacket Mass Flow Meter V-type mass flow meter Ultra-low temperature mass flowmeter Gas mass flow meter High pressure mass flowmeter Coriolis force on-line densitometer Tuning fork online density/concentration meter
          Tuning fork online density/concentration meter
          音叉在線密度/濃度計(jì)

          Applicable mediumLiquid fluid, slurry, suspension, high viscosity fluid, etc.

          Not applicable medium Solid medium

          0411-

          84409900 / 84403377

          Online consulting Online message
          Product introduction


          Tuning fork density and concentration meter


          Tuning fork density meters are used to measure the density of liquid media in tanks and pipes. Density measurement is an important process control in the production process of a product. The tuning fork density meter can be used as an indicator of other quality control parameters such as solid content or concentration value. It can meet the various measurement requirements of users for density, concentration and solid content.


          Working principle


            Tuning fork series online density and concentration meters use acoustic frequency signal sources to excite the metal tuning fork and make the tuning fork vibrate freely at the center frequency. This frequency has a corresponding relationship with the density of the contact liquid. Therefore, the frequency can be analyzed Measure the density of the liquid, and then perform temperature compensation to eliminate the temperature drift of the system; and the concentration can be calculated according to the relationship between the density and concentration of the corresponding liquid at a temperature of 20 ℃.

          Liquid Density Meter

          Particle restriction

          Gas

          Maximum liquid viscosity

          Particle diameter

          Suspended particles%


          <10Micron 

          <=40



          10~50 Micron

          <=20

          Generally not used

          2000CP



          advantage


          ? Fully integrated "plug and play, maintenance-free" density measurement

          ? Continuous measurement

          ? No moving parts, low maintenance

          ? Long rod type is suitable for use in open tanks and sealed tanks

          ? The length of the long pole can be up to 2 meters

          ? Provide materials including 316L, Kazakhstan C, zirconium, etc.

          ? Allow a small amount of solids and bubbles

          ? Density, standard density or special calculated value (solid percentage, concentration, specific gravity, etc.), 4-20 mA output

          ? Not easily affected by temperature and pressure

          ? In-line density meter is suitable for working under high pipeline pressure

          ? Provide temperature sensor


          Typical application


          Petroleum retail channel

          Combined volume flow meter for mass flow

          Winemaking concentration detection acid/alkali concentration control evaporator control

          End-point detection solvent separation in batch reactions

           

          Typical industry


           Petroleum and petrochemical industry       -Interface inspection-multi-oil pipeline

            Wine industry                                           -Quality control-continuous online

            Organic and inorganic chemical materials 

          Leak detection – underground storage tanks suitable for salt water

            Pharmaceutical Industry                            --Alcohol blending

            Mineral processing (clay, carbonate, silicate)  --Chinese medicine concentrate

            Battery industry                                         -density of lithium hydroxide, electrolyte, sulfuric acid solution


          Precautions


          Due to the needs of the technological process, the tuning fork density meter is often installed on the site with relatively harsh working conditions. In order to minimize the harshness of the working conditions of the density sensor, pay attention to the following:


          ★The tuning fork density meter should be installed as far as possible where the temperature gradient and temperature change are small, and there is no impact or vibration.

          ★ The measured medium is not allowed to freeze, otherwise the sensing element will be damaged and the tuning fork density meter will be damaged.

          ★ Prevent contact with corrosive or overheated measured medium.

          ★ Prevent the scum from depositing in the tank.

          ★ It should be handled gently to prevent damage to the tuning fork density meter.

          ★ Do not drop the instrument directly.

          ★ The instrument is forbidden to work above the rated pressure.

          ★ The pressure test is forbidden to exceed the specified test pressure.

          ★ Note It is forbidden to weld pipes when installing the tuning fork density meter.



                 


          Technical parameters


          Density performance
          Precision±0.003 g/cc±3.0 kg/m3
          The scope of work0 ~1.8 g/cc0~1800 kg/m3
          Repeatability±0.001 g/cc±1 kg/m3
          Process temperature influence (corrected)±0.0005 g/cc±0.5 kg/m3
          Process pressure influence (corrected)can be ignored
          (1) The above accuracy is applicable to the calibration range of 0.6~1.5 g/cc (600-1500 kg/m3).
          (2) The viscosity of the liquid can reach up to 2000CP.
          (3) Temperature influence refers to the maximum measurement deviation caused by the temperature of the process fluid deviating from the factory calibration temperature.
          (4) Pressure influence is defined as the change in sensor flow and density sensitivity caused by the deviation of the process pressure from the calibration pressure.
          TemperatureSpecification
          Process temperature–20 °C~+100 °C
          Ambient temperature–20 °C ~+85 °C
          Temperature Coefficient0. 1kg/m3/℃(After correction)
          Built-in temperature sensorPT100
          Structural materials
          Wetted partsSS316L、H C、Ti、zirconium
          Fork polishingStandard, electropolished
          shellIP65, Aluminum alloy
          Process connection

          Flange
          Process connection typeClamp

          Thread