欧洲尺码日本尺码美国欧洲LV_日本一码二码三码是什么尺码_99热热久久这里只有精品68_免费精产国品一二三产区区别,国语对白刺激做受xxxxx在线

          大連優(yōu)迅,優(yōu)迅儀表,大連優(yōu)迅儀器儀表有限公司
          CN EN

          The National Unified Service Hotline

          4006060830

          Coriolis Mass Flowmeter High Viscosity Mass Flow Meter Micro mass flow meter Heat Tracing Jacket Mass Flow Meter V-type mass flow meter Ultra-low temperature mass flowmeter Gas mass flow meter High pressure mass flowmeter Coriolis force on-line densitometer Tuning fork online density/concentration meter
          Heat Tracing Jacket Mass Flow Meter
          伴熱夾套質(zhì)量流量計

          Applicable mediumLiquid fluid, slurry, suspension, high viscosity fluid, etc.

          Not applicable medium Solid medium

          0411-

          84409900 / 84403377

          Online consulting Online message
          Product introduction


          Overview:


              The YS-MFU series heat-tracing jacketed mass flowmeter adopts a large-area thermal insulation jacket close to the surface of the flowmeter, which improves the heat exchange rate and enables the heat transfer medium in the cavities on both sides to exchange heat smoothly. The side heat tracing effect ensures the circulation of the heat transfer medium. The heat tracing and holding interval of the present invention can reach 60°C to 300°C, meets the requirement of high-temperature heat tracing of the medium to be measured on site, and can adapt to the requirements of increasingly complex site working conditions for high-precision measurement.


          Features:


              ● Using a multi-variable digital processing system. Strengthen the filtering of the signal, greatly improve the sensitivity and accuracy of signal measurement, speed up the response time of the system, and make the measurement more reliable;

              ● High measurement accuracy, general mass flow measurement accuracy can reach 0.1%-0.2%, density measurement resolution can reach 0.002-0.02g/cm^3; temperature measurement error is less than 0.5 degrees;

              ● High heat exchange efficiency, the heat transfer medium on both sides of the cavity can conduct heat exchange smoothly to ensure the heating effect;



          Technical parameters


          Heat Tracing Jacket Mass Flowmeter Reference Range Table


          ModelDiameter(mm)Recommended flow range(kg/h)Maximum flow range (kg/ h)
          YS-MFU-00330-1500-180
          YS-MFU-00660-4800-960
          YS-MFU-010100-18000-2100
          YS-MFU-015150-36000-4500
          YS-MFU-020200-60000-7200
          YS-MFU-025250-96000-12000
          YS-MFU-032320-180000- 21000
          YS-MFU-040400-300000-36000
          YS-MFU-050500-480000-60000
          YS-MFU-080800-1500000-180000
          YS-MFU-1001000-2400000-280000
          YS-MFU-1501500-4800000-600000


          Heat Tracing Jacket Mass Flowmeter General Technical Parameters

          Flow measurement accuracy:±0.1-0.2%
          ●Repeatability:±0.05-0.1%
          ●Density measurement range:0< ρ < 5g/ cm3
          ●Density measurement accuracy:±0.002g/cm3
          ●Temperature measurement range:-200~300℃
          ●Temperature measurement accuracy:±1℃
          ●Measured medium temperature:-50℃ - 200℃
          ●Applicable ambient temperature:-40℃ -80℃
          ●Material quality:Wetted part 316L shell 304
          ●Work pressure:Conventional 4MPa, high pressure can be customized
          ●output signal:4-20mA DC current signal, 0-10KHz frequency pulse signal、


          Pulse equivalent signal, RS485 communication signal
          ●Explosion-proof grade:Exd(ib) II CT6
          ●Protection:IP67