          Coriolis Mass Flowmeter High Viscosity Mass Flow Meter Micro mass flow meter Heat Tracing Jacket Mass Flow Meter V-type mass flow meter Ultra-low temperature mass flowmeter Gas mass flow meter High pressure mass flowmeter Coriolis force on-line densitometer Tuning fork online density/concentration meter
          Coriolis Mass Flowmeter
          科里奧利質(zhì)量流量計(jì)

          Applicable mediumLiquid fluid, slurry, suspension, high viscosity fluid, etc.

          Not applicable medium Solid medium

          0411-

          84409900 / 84403377

          Online consulting Online message
          Product introduction


          Overview:


              YS-MFU series mass flowmeter is a new type of high-precision flow and density measuring instrument developed by our company based on the Coriolis force principle and multivariable digital processing measurement technology. Realize the direct and precise measurement of fluid mass flow without any conversion or correction of pressure, temperature, viscosity, density, etc. Its structure is composed of two parts: sensor unit and transmitter unit. The instrument is designed and manufactured according to the national standard of intrinsically safe explosion-proof type. The mass flow meter can directly measure the quality of the fluid, with high accuracy (0.1%~0.2%), low installation requirements (the front and rear straight pipe sections of the instrument are not highly required), reliable and stable operation, and low maintenance rate.




          Features:

          It can directly measure the mass flow rate of fluid in a closed pipeline and can be used as a high-precision mass flowmeter (which is of great significance for energy measurement and production process control such as chemical reactions);

          It can directly measure the working density of the medium and can be used as a high-precision online density meter;

          MVDTM measurement technology (multivariate digital processing system) is adopted. The application of MVDTM technology enhances signal filtering, greatly improves the sensitivity and accuracy of signal measurement, accelerates system response time, and makes measurement more reliable;

          The adoption of MVDTM measurement technology makes the system composition more flexible and convenient. In many cases, MVD modules and sensors can form a complete flow measurement system without the need to configure a flow converter. For example, CNG, LNG refueling systems, quantitative control systems, flow or density unit parameter measurement systems, etc;

          High measurement accuracy, mass flow measurement accuracy can reach 0.1%~0.2%, and density measurement resolution can reach 0.001g/cm 3; Temperature measurement error is less than 0.5 degrees;

          ● Implementation of density and temperature measurement functions, which can derive medium concentration measurement functions (for two-component media);

          The installation requirements are not high (there are no requirements for upstream and downstream straight pipe sections), and the sensor has no mechanical movable parts and operates reliably;

          ● Wide applicability, the same sensor can be used for multiple media.




          Technical parameters

          Liquid mass flow meter reference range table

          ModelDiameter (mm)Recommended flow range(kg/h)Maximum  flow range(kg/ h)
          YS-MFU-00330-1500-180
          YS-MFU-00660-4800-960
          YS-MFU-010100-18000-2100
          YS-MFU-015150-36000-4500
          YS-MFU-020200-60000-7200
          YS-MFU-025250-96000-12000
          YS-MFU-032320-180000- 21000
          YS-MFU-040400-300000-36000
          YS-MFU-050500-480000-60000
          YS-MFU-080800-1500000-180000
          YS-MFU-1001000-2400000-280000
          YS-MFU-1501500-4800000-600000


          General technical parameters of liquid mass flow meters 

          ●Flow measurement accuracy:±0.1-0.2%
          Repeatability:±0.05-0.1%
          ●Density measurement range:0< ρ < 5g/ cm3
          ●Density measurement accuracy:±0.002g/cm3
          ●Temperature measurement range:-200-300℃
          Temperature measurement accuracy:±1℃
          ●Measured medium temperature:-50℃ - 200℃
          ●Applicable ambient temperature:-40℃ -80℃
          ●Material quality:Wetted part 316L   Shell 304
          ●Work pressure:Conventional 4MPa, high pressure can be customized
          ●output signal:4-20mA DC current signal, 0-10KHz frequency pulse signal,


          Pulse equivalent signal, RS485 communication signal
          ●Explosion-proof     grade:Exd(ib) II CT6
          ●Protection:IP67